Robust Detail E-FC-6
200mm deep floor beams shown for the purposes of illustration. Floor system also available in 150mm deep floor beams.
1. Screed (supplied by others)
- 65mm (min) sand cement screed or 40mm (min) proprietary screed, nominal 80kg/m2 mass per unit area.
2. Waterproof Membrane (supplied by others)
- 0.2mm (min) waterproof membrane.
3. Regupol Resilient Layer (supplied by others)
System installation
- 8mm thick Regupol E48 layer must be laid dimpled side down.
- Overlap all Regupol E48 joints (both along and across the roll) by at least 50mm and tape all joints using Regupol tape.
- Turn up Regupol E48 at walls to ensure screed will not touch the walls and is of sufficient length to lap under wall linings and skirting.
- Lay a waterproof membrane (min 0.2mm thick) over the entire floor.
4. Concrete Infill
- Nominal 50mm in-situ concrete infill between floor beams to seal floor.
- 25mm (min) concrete topping covering cut rows (150mm deep floor system)
5. Structural Floor
- 150 or 200mm deep precast concrete floor beams.
- 100mm deep dense aggregate concrete infill blocks (rebated blocks used in conjunction with 150mm deep beams).
- 300kg/m2 (min) mass per unit area (inclusive of in-situ concrete infill).
6. Ceiling (supplied by others)
Floor depth requirements and ceiling treatments.
- All E-FC-6 floors must have a minimum depth of 300mm between top of beam and ceiling board.
- Only suspended metal frame ceiling systems may be used.
- Min 50mm mineral fibre quilt (min 10kg/m³) in the ceiling void to cover whole ceiling board area.
- One layer of nominal 10kg/m² gypsum-based board.